Sony's IMX742 image sensor for endoscopes is designed for installation at the distal end of single-use (disposable) medical endoscopes. To help prevent infection transmission and improve workflow efficiency, demand is growing for single-use endoscopes, particularly those that require compact sensor sizes compatible with increasingly small diameter insertion parts, as well as high image quality, stable signal transmission, and other performance improvements.
The IMX742 is a CMOS image sensor that can meet these requirements. It is the first in the industry*1 to achieve 5 m long-distance transmission*2 with an ultra-compact size of 1 mm × 1 mm and a high digital image resolution of approximately 0.51 effective megapixels. The noise resistance and excellent S/N performance that can only be achieved with such digital output allows this sensor to provide high-visibility imaging even in low-light environments. Further, the IMX742 uses proprietary bi-directional communication technology to both reduce the pin count and achieve stable image transmission. This contributes to device miniaturization and improved performance, meaning the IMX742 can be mounted on small-diameter endoscopes that are less invasive for patients during testing and procedures in medical settings.

*1) Among CMOS image sensors for medical use endoscopes. According to Sony research (as of announcement on October 22, 2026).
*2) Transmission distance confirmed in a Sony evaluation environment using an AWG44 cable.

Features

Product Lineup

PDF Model name Image size Effective pixels
PDF IMX742-AQN Diagonal 1.02 mm
(1/17.7 type)
Approx. 0.51 megapixels

Technology

Achieves digital output, 0.51 megapixels, and 60 fps with an ultra-compact 1 mm × 1 mm design

The IMX742 integrates a variety of diverse functions onto an incredibly small chip of 1 mm × 1 mm. As the analog output method has been the mainstream for CMOS image sensors for single-use endoscopes, the IMX742 is equipped with an analog-digital (A/D) converter, enabling digital output. Further, not only does it offer a resolution of 720 × 720 (approx. 0.51 megapixels) but, at full pixel output, it can capture images at up to 60 fps, approximately twice the frame rate of typical single-use endoscope applications. By integrating these functions in a highly balanced manner, the IMX742 achieves an ultra-compact design as well as smooth image capture capabilities that track even rapid movement.

Small chip size package (CSP)

Flexible endoscopes require increasingly smaller insertion diameters to reduce patient burden. To address these requirements, Sony developed the ultra-compact IMX742 CMOS image sensor.
The IMX742 has a CSP cavity-less structure. Conventional CSP designs use resin around the perimeter of the chip to bond the cover glass and sensor, creating a cavity between them. Because this resin is not optically optimized, it must be placed outside the active pixel area, requiring a certain peripheral width to maintain bonding strength.
In contrast, IMX742 adopts a resin that addresses both the optical properties and bonding strength. This allows the resin layer to be formed across the entire chip area between the cover glass and sensor, eliminating the cavity structure. As a result, the peripheral resin bonding area required in conventional cavity structures is eliminated, enabling the IMX742's ultra-compact 1 mm × 1 mm design.

Photo of the ultra-compact design achieved with the IMX742
The ultra-compact design achieved with the IMX742
Illustration of the CSP structure comparison

High frame rate of up to 60 fps at full-pixel output

When observing tissue through an endoscope, a low frame rate can increase the risk of missing important visual information, particularly when the endoscope or subject is moving. The table below compares images of stomach tissue containing a model tumor captured at 60 fps and 30 fps over the same time period.

Comparison images of high-frame-rate photography in missing targets

In this example, portions of the tumor visible in the 60-fps sequence are not captured sufficiently in the 30-fps sequence. By capturing more images within the same period of time, the IMX742 increases opportunities to capture visual information and helps reduce the risk of missing important details.
In addition, the IMX742 supports high-frame-rate imaging that helps reduce image distortion and unnatural appearance caused by rolling-shutter effects when imaging moving objects, contributing to more natural-looking images.

Excellent noise performance under low-light

The IMX742 incorporates an on-chip analog-to-digital (A/D) converter that digitizes image signals within the sensor. Compared with conventional analog output image sensors, this helps reduce noise introduced during signal transmission and enables excellent noise performance, particularly in low-light environments.
As a result, the IMX742 delivers clearer, lower-noise images even under low light conditions, helping improve visibility of the observed area and facilitating image observation.

Equivalent to conventional analog output

Image showing corresponding analog output with a conventional device
Graininess and vertical lines are prominent, making details difficult to see

IMX742

Image captured using the IMX742
Reduces graininess and vertical lines and makes details easy to see

Long-distance (5 m) transmission through bi-directional communication

Using proprietary bi-directional communication technology, SSS has achieved stable transmission even across 5 m cables.*2 In addition, image data and control signals are transmitted through the same pin, eliminating the need for a dedicated input clock signal. This reduces the number of required signal pins from five in conventional systems to just two.
By eliminating multiple signal pins and simplifying wiring, the IMX742 supports greater design flexibility while enabling its ultra-compact 1 mm × 1 mm sensor size.

Example of a conventional digital connection structure
A digital connection structure using the IMX742

*3) Excluding the power and GND lines.

Low-power-consumption design

The IMX742 achieves low power consumption for the sensor unit at 40 mW (at 60 fps) or 30 mW (at 30 fps).*4 In addition, its excellent low-light noise performance enables clear image capture even under low-light conditions. This can reduce the required output of LED light sources and the associated driver load, contributing to lower power consumption at the system level.
Furthermore, the IMX742's high sensitivity relaxes illumination requirements for endoscope systems, providing greater flexibility in light source and circuit design. These advantages support the development of smaller and more advanced endoscope systems, particularly for devices with limited space at the distal end or for ultra-thin endoscopes.

*4) During all-pixel output at either 60 fps or 30 fps.

Specifications

Model name IMX742-AQN
Device structure Back-illuminated structure
Image size Diagonal 1.02 mm (Type 1/17.7)
Effective pixels 720 (H) × 720 (V)
Approx. 0.51 megapixels
Unit cell size 1.00 μm (H) × 1.00 μm (V)
Chip size 1.00 mm (H) × 1.00 mm (V)
Frame rate 30 fps / 60 fps
Power supply 2.7 V / 1.2 V / -1.2 V
Shutter mode Rolling shutter, Global reset
Input/output interface Bi-directional communication
Filter Bayer
CRA 30 deg
Package 6-pin, WCSP

Download

IMX742-AQN Product Overview

This document summarizes the product overview, features, and specifications.

Information on connection solutions compatible with the IMX742

Register to download contact information and details on the FPGAs and SoCs verified for connection with the IMX742's bi-directional communication interface.

Related Products & Solutions

* This product is not a medical device and has not been evaluated or approved by the for medical use. This product is just a part and is intended for integration into other systems, including those that may be certified by medical device manufacturers.
* The products listed on this page are not intended for medical use in Hong Kong, and this page is not intended to advertise our products in Hong Kong.

Contact us

Inquire about products and services

Contact us

E-mail Newsletters

Find the latest information on our newsletter for industrial and security applications.